Patient Monitor Accuit Sign 8 MDX-USA

Current price is: $2.00. Original price was: $2.72.

Feature:
High resolution 12.1″color TFT display
Suitable for adult, pediatric and neonatal patient
Color TFT Screen, waveform up to 8 channels
Operation modes: Diagnostic, Monitor, Surgery
Light and portable with Built-in rechargeable lithium battery
 UP to 10 kinds of monitor parameters

99 in stock

Current price is: $2.00. Original price was: $2.72.

99 in stock

Add to cart
Buy Now
Category:
Feature:
High resolution 12.1″color TFT display
Suitable for adult, pediatric and neonatal patient
Color TFT Screen, waveform up to 8 channels
Operation modes: Diagnostic, Monitor, Surgery
Light and portable with Built-in rechargeable lithium battery
 UP to 10 kinds of monitor parameters
 Arrhythmia analysis, pace-marker detection and S-T Segment analysis
72 hour storage and review of trend grams and tables
500 NIBP measurement date can be storage and recall
Electro surgical unit and defibrillation protected
Networkable with central monitoring system
ECG
5-lead or 3-lead selectable
Input: 5-lead :RA; LA; RL; LL; V or R; L; N; F; C
ECG waveforms of 7-leads display on the same screen
Lead selection :I; II; III; avR; avL; avF; Vx
ECG waveform :2 channels
Gain selection :12.5mm/s, 25mm/s, 50mm/s
Accuracy :±1bpm or ±1%, whichever is greater
Protection :Withstand 4000VAC/50Hz voltage in isolation against electrosurgical and defibrillation
Calibration signal :1mV±5%
Alarm range: Adult :15-300bpm
Pediatric/Neonatal :15-350bpm
Arrhythmia analysis and S-T segment analysis
Alarm range :-2.0mV~2.0mV
S-T segment detection Measurement rang :-0.2mv~2.0mv
Alarm :Yes, audible and visual alarm, alarm events review
NIBP
Operation modes :Manual/Automatic/STAT
Measurement unit :mmHg/KPa selectable
Measurement types :Systolic, Diastolic and Mean
Over-pressure protection :YES
Resolution :1mmHg
Accuracy :Mean error and standard deviation per ANSI/AAMI SP-10
Alarm :Systolic, Diastolic, and Mean
Auto measure time :Adjustable
Measurement rang :10-270mmHg
500 NIBP measurement date can be storage and recall
SpO2
Measurement range :0-100%
Accuracy :70-100%, ±2% 0-69%, upspecified
Alarm range :0-100% Pulse rate
Range :20-254bpm
Accuracy :±3bpm
Respiration
Method :RA-LL impedance
Pediatric/Neonatal :6-150rpm
Alarm range: Adult :6-120rpm
Pediatric/Neonatal :6-120rpm
Apnea alarm :YES
Temperature
Channel :Dual-channel
Alarm range :0-50℃
Apnea :0.1℃

 

Reviews

There are no reviews yet.

Be the first to review “Patient Monitor Accuit Sign 8 MDX-USA”

Your email address will not be published. Required fields are marked *